NAY2Y-J 0,6/1kV

NAY2Y-J 0,6/1kV
To be confirmed
NAY2Y-J 0,6/1kV
Product Views: 3536
0,00 zł

Power cables with aluminum wires, PVC insulation and PE coating.

PVC insulated and sheathed cables for the transmission of electricity. Designed for installation in the air, in the ground, under water, inside buildings and in cable ducts.

Construction:

  • Cores: Aluminum, round class 1 (RE) or round, round compressed class 2 (RM) or sector solid one (SE) or sectoral multi-wire class (SM) according to EN 60228
  • Insulation: Polwinit type DIV4 according to HD 603.1
  • Coating: polyvinyl
  • Filling: Special rubber compound
  • Coating color: black, UV
  • Identification of veins:
    • NAY2Y-J:
      • 1-wire: yellow-green
      • 2-wire: yellow-green, black
      • 3-wire: yellow-green, blue, brown
      • 4-wire: yellow-green, brown, black, gray
      • 4-wire for specific applications: yellow-green, blue, brown, black
      • 5-wire: yellow-green, blue, brown, black, gray
    • NAY2Y-O:
      • 1-wire: black
      • 2-wire: blue, brown
      • 3-wire: brown, black, gray
      • 3-wire for specific applications: blue, brown, black
      • 4-wire: blue, brown, black, gray
      • 5-wire: blue, brown, black, gray, black

Characteristic:

  • Maximum temperature during cable operation: + 70 °C
  • Minimum ambient temperature for permanently laid cables: -30 °C
  • The minimum ambient temperature for cable laying: -5 °C
  • Maximum core temperature during short-circuit:
    • + 160 ° C for a cross-section of ≤ 300 mm²
    • + 140 ° C for a section> 300 mm²
  • Minimum bending radius: 12 x D, D - outer diameter of the cable
  • Maximum allowable tensile stresses: 30 N / mm
  • Test voltage AC 50Hz 5min: 4kV
  • Standard packaging: 1000m on drums. It is possible to offer other lengths and types of packaging

Compliant with: VDE 0276-603, IEC 60502-1

Certificates: VDE


Industrial grade
Operating temperature to 70°C
Cable parameters
Minimum bending radius 12D
Core Aluminium
Insulation Polyvinyl chloride (PVC)
Installation temperature -5°C to 70°C
Maximum short circuit temperature 160°C, 140°C
Test voltage 4 kV
Standard packaging On drums
Coating Polyethylene
Minimum ambient temperature -30°C
Outer diameter [mm] 10.0, 11.5, 12.5, 14.7, 16.1, 17.8, 18.3, 19.5, 20.3, 20.8, 21.1, 21.6, 22.0, 22.1, 22.8, 23.6, 24.0, 24.1, 25.0, 25.4, 25.5, 25.6, 26.2, 26.6, 27.3, 27.4, 27.6, 28.9, 29.1, 29.4, 30.4, 31.3, 31.8, 32.1, 32.3, 33.1, 33.3, 34.1, 35.5, 35.7, 36.0, 36.1, 36.5, 37.6, 37.8, 39.3, 39.8, 40.2, 40.4, 41.5, 41.6, 43.7, 43.8, 44.3, 45.6, 46.4, 48.4, 49.8, 50.1, 50.5, 50.7, 50.9, 53.7, 55.4, 56.0, 56.3, 56.9, 61.0, 62.3, 68.9
Cable weight [kg/km] 109, 154, 189, 255, 328, 399, 435, 513, 526, 558, 567, 631, 633, 641, 698, 756, 770, 771, 795, 805, 855, 919, 975, 977, 1017, 1034, 1141, 1156, 1158, 1194, 1298, 1378, 1395, 1401, 1485, 1500, 1530, 1672, 1682, 1781, 1790, 1825, 1858, 1879, 1975, 1980, 2163, 2258, 2326, 2402, 2439, 2749, 2776, 2858, 2916, 2918, 2950, 3416, 3440, 3476, 3588, 3625, 3642, 4341, 4401, 4435, 4439, 4635, 5577, 5652, 6802