Menu
Your Cart

OnGcrekgż-G (Z) 6/10 kV

OnGcrekgż-G (Z) 6/10 kV
To be confirmed
OnGcrekgż-G (Z) 6/10 kV
Product Views: 3407
0,00 zł

Mining wires shielded for rated voltage 6/10 kV.

Construction:

  • Working and protective veins: Copper, copper tinned multi-wire class 5 according to PN-EN-60228
  • Screen on working cords: GP semiconductor rubber according to PN-E 29100: 1989
  • Insulation: IEP heat-resistant rubber according to PN-E 29100: 1989
  • The color of the insulation of the veins: Natural
  • Screen on the insulation of working cores: GP semiconductor rubber according to PN-E 29100: 1989
  • Tire inner layer: Of rubber type ON-4 according to PN-E-29100: 1989
  • Strengthening braid: Made of polyamide yarn
  • Tire outer layer: Of rubber type ON-4 according to PN-E-29100: 1989
  • Tire color: Red or black

Characteristic:

  • Application: For powering mining open-cast mining machines, for work in continuous coiling and unwinding conditions
  • Explanation of the conductor symbol: OnGcrekgż-G (Z) - power cable with copper conductors, with heat-resistant, reduced rubber insulation (Gcr) and flame retardant rubber (On), with shielded conductors semi-conductive rubber (ekgż), mining (-G) , for folding and developing ((Z))
  • Example of wire marking: OnGcrekgż-G (Z) four-wire conductor for 6/10 kV voltage with a cross section of 70 mm2 working wires, 35 mm2 protective conductor: OnGcrekgż-G (Z) 3x70 + 3x35 / 3 mm2 6/10 kV cable according to ZN- 95 / MP-13-K104
  • Maximum core temperature during insulation operation: + 90 °C
  • Working range in the temperature range: -40 °C to + 50 °C
  • Minimum bending radius: 10 x D, D - outer diameter of the wire
  • Assay voltage: 17 kV working veins
  • Packing: Cable drums

Compliant with: ZN-95 / MP-13-K 104

Certificates: EMAG


Industrial grade
Operating temperature -40°C to 90°C, -40°C to 50°C
Cable parameters
Minimum bending radius 12D
Core Copper
Shield Semi-conductive rubber
Insulation Heat-resistant rubber
Maximum allowable tensile stresses 0.45 kN, 0.72 kN, 1.125 kN, 1.575 kN, 2.25 kN, 3.15 kN, 4.275 kN, 5.4 kN, 6.75 kN, 8.325 kN
Test voltage 17 kV
Standard packaging On drums
Tire Rubber
Outer diameter [mm] 34.7, 37.1, 40.9, 42.4, 46.7, 52.0, 56.5, 58.9, 64.3, 69.1
Cable weight [kg/km] 1650, 2025, 2900, 2525, 3700, 4725, 5800, 6875, 8225, 9725
Working conductor cross section [mm2] 10.0, 16.0, 25.0, 35.0, 50.0, 70.0, 95.0, 120.0, 150.0, 185.0

Write a review

Note: HTML is not translated!
Bad Good
We use cookies to offer you the best experience on our site. By continuing to browse the site, You are agree to use cookies.