4-slots Ethernet I/O unit with Modbus protocol and three built-in COM ports. I-8431-80-MTCP and I-8831-80-MTCP are remote I/O expansion units to expand I-8K and I-87K I/O modules over the Ethernet for industrial monitoring and controlling application..
LPF RFID Coded Non Contact Safety Interlock SwitchIDEM’s coded RFID non-contact safety interlocks are designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO14119. They are available in two coding types: Master or U..
12.1" Touch Panel PC with Intel® Core™ i5/i3, Pentium® or Celeron® Processor. The VIO-100/PC300 and VIO-200/PC300 series Panel PC is based on 5th Gen. Intel® Core™ i5-5350U (2.9GHz) / i3-5010U (2.1GHz) or Celeron® 3765U (1.9GHz) Dual Core processor. ..
Smart Camera Framework for ITS with Intel® Atom™ processor and enclosure with IP67 protection. iVIS-200 is a Atom™ E3845 processing unit as part of an innovative smart camera framework, where you can build up your own x86-based smart camera by integr..
Industrial, universal 1-port RS-232/422/485 serial device server with one Ethernet port.
It provides 1 port RS-232/485/422 (RS232, DB9M; RS485/422, 5 bit terminal block) and 1 port 10/100Base-T(X). It makes them ideal choice for connecting decentra..
Tiny Ethernet module with 4-channel Digital Outputs (PNP, Source). Providing various digital I/O functions, the tET/tPET series is an IP-based Ethernet I/O monitoring and control module. The module can be remotely controlled through a 10/100 M Ethern..
Industrial 8-channel Input and 8-channel Digital Output Module to Modbus RTU, with RS485 interface. Cechy:INPUT / OUTPUT: 8 digital inputs, 8 PNP outputsOUTPUT / INPUT: RS485 - Modbus Slave (ASCII, RTU)Mounting on a DIN rail8 configurable 32-bit coun..
Mitsubishi Electric Citiy Multi systems to Modbus Gateway. The newer version of this device is IN770AIR00SO000The ME-AC-MBS (INMBSMIT050C000) IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of Mitsubishi E..
Industrial Embedded Redundant Ethernet Switch with 7 100M ports and 3 1000M ports. IEM7110-3G is the world's first intelligent 1000M embedded industrial Ethernet switch module designed for Ethernet equipment connection in industrial application. It s..
Industrial Modbus RTU slave to SNMP manager converter, housing type A (slim), DIN rail mount. HD67175 allows you to connect a Modbus Master net (for example a PLC, SCADA System, etc) with a SNMP Agent net in order to exchange the informations between..
Industrial Modbus TCP Slave to Modbus Master converter with two Ethernet ports, housing type A (slim), DIN rail mount. HD67508-A1-422 allows you to connect some Slaves Modbus RTU to a Master Modbus TCP over Ethernet. It has 2 LAN ports, which allows ..
KNX to Modbus Gateway. Model IN701KNX6000000 Modbus Server RTU &TCP - KNX- 600 points. Integrate any KNX device or installation, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible KNX ..
CAN485 is used for data exchange between CAN-bus field bus and RS-485 bus interface converter, and supports Modbus RTU protocol. CAN485 interface converter integrated a RS-485 channel and a CAN bus channel can be easily embedded using RS-485 interfac..
Modbus RTU or TCP to BACnet converter. Integrate any Modbus RTU or TCP Slave device, or both at the same time, with a BACnet BMS or any BACnet IP or BACnet MS/TP controller. It fulfills B-AAC BACnet profile. BTL approved.Specification:Ports:Port A:1x..
Isolated (3000V) RS-485/422 repeater or RS-232 to RS485/422 converter. It can use one function at the same time. The product must have 12-36VDC power input, optic-electrical isolation more than 3KV. Have small volume, 3000m transfer distance, high ra..