Menu
Your Cart

INMBSMIT001I000 Mitsubishi Electric to Modbus RTU RS-485 gateway with DIP setup

INMBSMIT001I000 is Mitsubishi Electric to Modbus RTU RS-485 gateway with DIP setup, temp. -40…85°C.

INMBSMIT001I000 - Mitsubishi Electric to Modbus RTU RS-485 gateway with DIP setup
3 year warranty 5-7 days
INMBSMIT001I000 Mitsubishi Electric to Modbus RTU RS-485 gateway with DIP setup
  • Stock: 5-7 days
  • Brand: Intesis
  • Model: INMBSMIT001I000
1 137,87 zł
2 pieces or more 1 080,98 zł
5 pieces or more 1 058,22 zł
10 pieces or more 1 024,08 zł
26 pieces or more 967,19 zł
51 pieces or more 864,78 zł
A proven choice for industrial installations.
Ask for compatibility and model selection.
Additional discounts for registered customers.

Full design package: User manual, CE declaration, CAD, PDF, certificates and test reports

If you're preparing technical documentation or an installation design, you can receive a complete set of design materials for this model. This is a quick way to gather the required documents for audits, acceptance, or project documentation.

  • Device User Manual
  • CE Declaration of Conformity (EU Declaration of Conformity)
  • Mechanical DrawingsCAD (STEP/DWG) or high-quality PDF
  • Additional Certificates and Test Reports (if available for the model)
Request a package: User manual, CE declaration, CAD, PDF, certificates, test reports

Mitsubishi Electric AC to Modbus communication module, model INMBSMIT001I000 from Intesis.

The IntesisBox ME-AC-MBS-1 provides full, bi-directional monitoring and control of Mitsubishi Electric Domestic and Mr.Slim Air Conditioners over a Modbus RTU (RS-485) network.

INMBSMIT001I000 is designed for projects where air conditioning must be integrated into a PLC, BMS, SCADA, or any Modbus-based automation layer. Instead of relying on proprietary control logic or fragmented IR-only operation, the gateway exposes AC functions and statuses through Modbus RTU registers, enabling consistent mapping, predictable behavior, and faster commissioning across multi-zone installations.

Because the gateway is wired directly to the indoor unit, it can handle both control commands and feedback signals in real time. This covers everyday HVAC operation (mode selection, fan speed, and temperature setpoint) while also providing visibility into alarms, fault conditions, and selected internal variables. The result is a cleaner integration model: the building automation system can supervise comfort, energy usage, and service events without losing the ability for local users to operate the unit when needed.

Manufacturer code change
Old code: ME-AC-MBS-1
New code: INMBSMIT001I000
Technically identical product – only the name / SKU has changed.

Installation and configuration are intentionally simplified for field work. Setup is based on wiring the gateway to the AC indoor unit and applying the required DIP-SW configuration. No configuration software and no external power supply are required, which reduces installation time and minimizes the number of components in the panel. A consistent Modbus register mapping approach (used across multiple AC brands) helps shorten project engineering and speeds up replication across similar sites.

The gateway connects to Modbus RTU (RS-485) and supports multi-device networks: up to 63 devices can be connected to the same RS-485 line. This makes the solution practical for commercial buildings, hotels, offices, and multi-zone facilities where many indoor units must be supervised from one automation backbone.

Product features
  • Compact size for easier panel and ceiling-space installations
  • Fast and straightforward installation
  • No external power supply required
  • Direct connection to MODBUS RTU (RS-485); up to 63 ME-AC-MBS-1 devices can share the same network
  • Direct connection to AC indoor units
  • Configuration via built-in DIP switches and through Modbus RTU
  • Total control and supervision from the automation system
  • Real-time status of selected internal variables of the AC unit
  • Allows simultaneous use of the IR remote controller and Modbus RTU

The option to use the IR remote controller in parallel with Modbus RTU is especially useful in real buildings: the BMS can enforce schedules, limits, and supervisory logic, while local occupants retain a familiar interface for day-to-day adjustments. This helps keep both operational control and user comfort in balance.

Technical specifications
  • Dimensions: 93 x 53 x 58 mm
  • Weight: 85 g
  • Operating temperature: -40°C ~ 85°C
  • Storage temperature: -40°C ~ 85°C
  • Operating humidity: <95% RH, Non-condensing
  • Humidity: <95% RH, Non-condensing
  • Isolation voltage: 1000 VDC
  • Isolation resistance: 1000 MΩ
  • Modbus Media: compatible with Modbus RTU - RS485 network

With an operating range of -40°C to 85°C and electrical isolation rated at 1000 VDC, the gateway is suitable for demanding technical areas and helps improve reliability in RS-485 installations where noise, grounding differences, or long cable runs can be present.

Warranty INMBSMIT001I000: 36 months

tech_draw

Product code: INMBSMIT001I000

Write a review

Note: HTML is not translated!
Bad Good
1