Menu
Your Cart

FlameBlocker NTKOXSekwf 150/250V (300V)

FlameBlocker NTKOXSekwf 150/250V (300V)
To be confirmed
FlameBlocker NTKOXSekwf 150/250V (300V)
  • Stock: To be confirmed
  • Brand: TELE-FONIKA Kable
  • Model: FlameBlocker NTKOXSekwf 150/250V (300V)
0,00 zł

Halogen-free telecommunication, measuring and signaling ship cables with low smoke emission, collectively shielded with aluminum-polyester tape. Compliant with IEC 60092-376.

Construction:

  • Conductors: Circular stranded bare or tinned copper class 2 or class 5 acc. to IEC 60228
  • Insulation: Cross-linked polyethylene HF-XLPE 90ºC acc. to IEC 60092-351
  • Inner covering: Lapped with non-hygroscopic tape
  • Collective screen: Of aluminium/polyester tape with the metallic contact with a tinned copper drain wire
  • Sheath: Thermoplastic halogen free polyolefin compound type SHF1 acc. to IEC 60092-359
  • Colour of sheath: Grey, black or blue
  • Core identification: White with black printed numbers
  • Pair identification:
    • core a: blue (or black)
    • core b: white
    • with printed pair number

Technical Data:

  • Maximum conductor operating temperature: +90°C
  • Lowest ambient temperature for fixed installation: -40°C
  • Lowest installation temperature: -15°C
  • Minimum bending radius: 6 x D (D is the overall diameter of the cable)
  • Flame retardant: IEC 60332-3-22 Category A
  • Smoke emission: IEC 61034-2
  • Gases evolved during combustion:
    • IEC 60754-1: < 5 mg/g acid gas
    • IEC 60754-2: pH ≥ 4,3; conductivity ≤ 10 μSmm-1
  • Application: Cables are designed for interconnection of all sorts of instrumentation and communication equipment including that telephone equipment whose proper functioning is necessary for the safety of the ship
  • Standard length cable packing: 500 or 1000 m on drums. Other forms of packing are available on request
  • Approvals: DNV

Industrial grade
Operating temperature to 90°C
Cable parameters
Minimum bending radius 6D
Core Copper
Shield Aluminum-polyester tape
Insulation Polyethylene
Installation temperature -15°C to 90°C
Standard packaging On drums
Coating Thermoplastic halogen-free polyolefin
Filling Tape
Minimum ambient temperature -40°C
Resistance to flame spread IEC 60332-3-22
Fume emission during combustion IEC 61034-2
Outer diameter [mm] 6.2, 7.0, 7.1, 7.4, 7.9, 8.1, 8.2, 8.3, 8.5, 8.7, 9.2, 9.4, 9.6, 9.7, 10.0, 11.5, 11.6, 11.7, 11.8, 11.9, 12.2, 12.7, 13.0, 13.3, 13.6, 13.8, 14.0, 14.1, 14.3, 14.4, 14.8, 14.9, 15.3, 15.4, 15.6, 16.0, 16.3, 16.4, 16.7, 16.8, 17.0, 17.1, 17.3, 17.6, 17.9, 18.0, 18.1, 18.4, 18.8, 19.2, 19.3, 19.6, 19.8, 21.2, 21.6, 22.0, 22.2, 22.4, 22.7, 22.8, 23.1, 23.4, 24.1, 24.3, 24.4, 24.5, 25.4, 25.8, 26.1, 27.0, 27.4, 28.5, 29.0, 29.2, 30.0, 31.8, 32.3, 36.8, 37.4
Cable weight [kg/km] 45, 63, 109, 159, 223, 252, 290, 367, 463, 665, 57, 82, 144, 221, 258, 310, 361, 406, 527, 556, 664, 955, 84, 132, 237, 371, 432, 534, 612, 705, 788, 921, 971, 1159, 1706, 68, 81, 96, 111, 117, 163, 184, 213, 238, 263, 269, 339, 348, 369, 427, 486, 62, 108, 156, 219, 247, 284, 359, 453, 649, 145, 360, 405, 525, 554, 661, 949, 80, 126, 225, 350, 407, 504, 576, 663, 741, 864, 912, 1088, 1597, 69, 112, 212, 262, 268, 337, 347, 368, 425, 483