- Stock: To be confirmed
- Brand: TELE-FONIKA Kable
- Model: H05VV-F, H05VVH2-F, 05VV-F, 05VVH2-F 300/500V
Multi-conductor cables with PVC insulation and sheath, for mobile and portable receivers.
In home rooms, kitchens, offices; for household appliances, also in humid and wet rooms, with medium mechanical loads (eg washing machines, centrifuges and refrigerators). It can be used for kitchen and heating appliances, provided that if there is no danger of contact with hot elements and is not exposed to other heat influences. It is not suitable for outdoor installations in the open air, in industrial or agricultural buildings for portable tools except for household appliances. Acceptable for use in tailoring plants. It can be permanently laid eg in furniture, decorative buildings, adjustable walls.
Construction:
- Cores: Made of soft copper wire, multi-wire flexible class 5 according to PN-EN 60228
- Insulation: TI2 acc. EN 50363-3
- Coating: TM2 acc. EN 30363-4-1
- Coating color: White, black, gray or other according to the customer's order
- Identification of veins:
- 2-wire: blue, brown
- 3-wire: green-yellow, blue, brown
- 4-wire: green-yellow, brown, black, gray
- 5-wire: green-yellow, blue, brown, black, gray
Characteristic:
- Explanation of symbolism:
- H05VV-F - Cable manufactured in accordance with the harmonized standard (H) for rated voltage 300 / 500V (05) with PVC insulation (V) and PVC (V) sheath, with multi-wire flexible cables (F)
- H05VVH2-F - Cable manufactured in accordance with the harmonized standard (H) for rated voltage 300 / 500V (05) with PVC insulation (V) and PVC (V) flat sheath (H2) with flexible multi-wire flexible (F)
- Maximum temperature of the wire during cable operation: + 70°C
- The minimum ambient temperature for permanently laid cables: -40°C
- The minimum ambient temperature for laying cables: -5°C
- Maximum core temperature during short circuit: + 150°C
- Test voltage 50 Hz: 2000V
- Minimum bending radius: 6 x D, D - outer diameter of the cable or smaller dimension of the flat cable
- Standard packaging: In reels of 50 or 100 m and on drums of 500 or 1000 m. It is possible to offer other lengths of sections and types of packaging
Reaction to fire:
- CPR - reaction to fire class (according to EN 50575): Eca
Compliant with: PN-EN 50525-2-11, BS-EN 50525-2-11
Industrial grade | |
Operating temperature | to 70°C |
Cable parameters | |
Minimum bending radius | 6D |
Core | Copper |
Insulation | Polyvinyl chloride (PVC) |
Installation temperature | -5°C to 70°C |
Maximum short circuit temperature | 150°C |
Test voltage | 2 kV |
Standard packaging | Discs, On drums |
Coating | Polyvinyl chloride (PVC) |
Minimum ambient temperature | -40°C |
Number of wires in the cable | Multi-core |
Outer diameter [mm] | 5.8, 6.1, 6.2, 6.4, 6.6, 6.7, 6.8, 7.2, 7.3, 7.4, 7.6, 7.8, 8.0, 8.1, 8.3, 8.8, 8.9, 9.0, 9.2, 9.9, 10.0, 10.3, 10.8, 10.9, 11.1, 11.7, 11.8, 12.0, 12.1, 12.2, 12.4, 13.7, 13.8, 14.2, 14.6, 14.7, 14.8, 15.1, 16.2, 16.9, 17.1, 20.4, 20.9 |
Cable weight [kg/km] | 39, 43, 44, 50, 51, 57, 60, 61, 63, 69, 73, 78, 87, 90, 93, 98, 106, 118, 122, 124, 130, 136, 153, 156, 165, 185, 187, 199, 203, 209, 222, 223, 235, 257, 279, 287, 297, 325, 329, 337, 351, 402, 409, 415, 423, 434, 463, 473, 611, 717 |
Working conductor cross section [mm2] | 0.5, 0.75, 1.0, 1.5, 2.5, 4.0, 6.0 |